APC Double Conversion Online Smart UPS
Overview
Smart-UPS On-LineFeatures & Benefits
Availability
-
Intelligent battery managementMaximizes battery performance, life, and reliability through intelligent, precision charging.
-
Automatic internal bypassSupplies utility power to the connected loads in the event of a UPS power overload or fault.
-
Scalable runtimeAllows additional run time to be quickly added as needed.
-
Hot-swappable batteriesEnsures clean, uninterrupted power to protected equipment while batteries are being replaced
-
Automatic restart of loads after UPS shutdownAutomatically starts up the connected equipment upon the return of utility power.
-
Temperature-compensated battery chargingProlongs battery life by regulating the charge voltage according to battery temperature.
Marketing Features
-
Save time with easy and convenient remote accessibility.Network manageable via serial, USB or optional Ethernet. Includes Powerchute® Network Shutdown Software for convenient monitoring and control, safe operating system shutdown, and innovative energy management capabilities.
-
Low operating and maintenance costs with proven reliability and intelligent battery management.Intelligent battery management, pioneered by APC, maximizes battery performance and life through intelligent, precision temperature compensated charging. Automatic self tests insure battery reliability and warn customers in advance of battery replacement. Convenient, easy to connect, hot-swappable battery modules provide battery replacement without powering down.
-
Avoids costly power problems by keeping your IT equipment and data protected and available.Network grade power conditioning protects from damaging surges and disruptive noise. The double conversion architecture provides tight voltage regulation, frequency regulation ,and zero transfer time to battery during power events.
-
Peace of mind that comes with full equipment compatibility and reliability of a leaderProvides pure sine wave output which is recommended by server manufacturers using active power factor corrected (PFC) power supplies. Safety agency tested and approved means that you can deploy Smart-UPS with confidence that they meet or exceed the industry’s most rigorous standards.
Protection
-
Power conditioningProtects connected loads from surges, spikes, lightning, and other power disturbances.
-
Input power factor correctionMinimizes installation costs by enabling the use of smaller generators and cabling.
-
Safety-agency approvedEnsures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
-
Frequency and voltage regulationGives higher application availability by correcting poor frequency and voltage conditions without using the battery.
-
Cold-start capableProvides temporary battery power when the utility power is out.
-
Resettable circuit breakerEasy recovery from overloads; no need to replace a fuse.
-
Generator compatibleEnsures clean, uninterrupted power to protected equipment when generator power is used.
Serviceability
-
Audible alarmsProvides notification of changing utility power and UPS power conditions
-
Predicitive failure notificationProvides early-warning fault analysis ensuring proactive component replacement.
-
Disconnected battery notificationWarns when a battery is not available to provide backup power.
-
User-replaceable batteriesIncreases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
-
Automatic self-testPeriodic battery self-test ensures early detection of a battery that needs to be replaced.
Adaptability
-
Flash upgradeable firmwareInstall maintenance releases of firmware remotely using FTP.
-
Plug-and-Play external batteriesEnsures clean, uninterrupted power to the loads when adding extra runtime to the UPS.
-
Rack/Tower convertibleProtects the initial investment in the UPS when migrating from tower to rack-mount environment.
Manageability
-
InfraStruXure Manager CompatibleEnables centralized management via the APC InfraStruXure Manager.
-
SmartSlotCustomize UPS capabilities with management cards.
-
LED status indicatorsQuickly understand unit and power status with visual indicators.
-
Serial connectivityProvides management of the UPS via a serial port.
-
Network manageableProvides remote power management of the UPS over the network.
Detailed Tech Specification
Output
-
Output power capacity
2.1 KWatts / 3.0 kVA
-
Max Configurable Power (Watts)
2.1 KWatts / 3.0 kVA
-
Nominal Output Voltage
230V
-
Output Voltage Note
Configurable for 220 : 230 or 240 nominal output voltage
-
Output Voltage Distortion
Less than 3%
-
Output Frequency (sync to mains)
50/60 Hz +/- 3 Hz user adjustable +/- 0.1
-
Other Output Voltages
220, 240
-
Load Crest Factor
3 : 1
-
Topology
Double Conversion Online
-
Waveform type
Sine wave
-
Output Connections(2) IEC 320 C19 (Battery Backup)(8) IEC 320 C13 (Battery Backup)(2) IEC Jumpers (Battery Backup)
-
Bypass
Internal Bypass (Automatic and Manual)
Input
-
Nominal Input Voltage
230V
-
Input frequency
50/60 Hz +/- 5 Hz (auto sensing)
-
Input Connections
British BS1363A, IEC-320 C20, Schuko CEE 7/EU1-16P
-
Cord Length
2.44meters
-
Input voltage range for main operations
160 – 280V
-
Input voltage adjustable range for mains operation
100 – 280 (half load)V
-
Number of Power Cords
1
-
Other Input Voltages
220, 240
Batteries & Runtime
-
Battery type
Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof
-
Included Battery Modules
2
-
Typical recharge time
2.5hour(s)
-
Expected Battery Life (years)
3 – 5
-
RBC Quantity
1
-
Extendable Run Time
1
-
Runtime
-
Efficiency
Communications & Management
-
Interface Port(s)
RJ-45 Serial , Smart-Slot
-
Control panel
LED status display with load and battery bar-graphs and On Line : On Battery : Replace Battery : Overload and Bypass Indicators
-
Audible Alarm
Alarm when on battery : distinctive low battery alarm : overload continuous tone alarm
-
Emergency Power Off (EPO)
Yes
-
Available SmartSlot™ Interface Quantity
1
Surge Protection and Filtering
-
Surge energy rating
555JJoules
-
Filtering
Full time multi-pole noise filtering : 0.3% IEEE surge let-through : zero clamping response time : meets UL 1449
Physical
-
Maximum Height
432mm , 43.2CM
-
Maximum Width
130mm , 13.0CM
-
Maximum Depth
660mm , 66.0CM
-
Rack Height
3U
-
Net Weight
54.55KG
-
Shipping weight
63.64KG
-
Shipping Height
347mm , 34.7CM
-
Shipping Width
603mm , 60.3CM
-
Shipping Depth
980mm , 98.0CM
-
Color
Black
-
Master Carton Units
1.0
-
Units per Pallet
6.0
Environmental
-
Operating Temperature
0 – 40 °C
-
Operating Relative Humidity
0 – 95% non-condensing %
-
Operating Elevation
0-3000meters
-
Storage Temperature
-15 – 45 °C
-
Storage Relative Humidity
0 – 95% non-condensing %
-
Storage Elevation
0-15000meters
-
Audible noise at 1 meter from surface of unit
55.0dBA
-
Online thermal dissipation
609.0BTU/hr
-
Protection Class
IP 20
Reviews