Galaxy VS UPS 40kW 400V, 2 internal 9Ah smart modular battery strings, expandable to 4, Start-up 5×8 – GVSUPS40KB4HS
- Max Configurable Power (Watts) : 40 kWatts / 40 kVA
- Other Input/Output Voltages : 380 V, 415 V
- Waveform type : Sine wave
- Bypass : Built-in static bypass
- Battery type : Internal modular battery, VRLA
- Warranty : 1 Year
PN : GVSUPS40KB4HS
Overview
Highly efficient, easy-to-deploy 40kW, 400V 3-phase UPS that brings best-in-class power protection and low total cost of ownership to edge, small and medium data centers, as well as to critical infrastructure in commercial and industrial applications. Includes 5×8 start-up service and 2 smart high-capacity modular battery strings, expandable to 4 strings for extended runtime. Runtime charts available in the Documents tab.
Published on lastbestdeal.com
Detailed Tech Specification
Main |
|
Main Input Voltage | 400 V 3 phases |
Other Input Voltage | 380 V 415 V |
Main Output Voltage | 400 V 3 phases |
Other Output Voltage | 380 V 415 V |
Rated power in W | 40 kW |
Rated power in VA | 40 kVA |
output connector type | Hard wire 5-wire (3P + N + E) 1 |
Battery type | Internal modular battery VRLA |
provided equipment | Battery modules ship installed Dust filter EcoStruxure IT ready (UPS) Installation guide Integrated network management Power modules ship installed Start-up service |
General |
|
Bypass voltage tolerance | +/- 10 % |
Redundant | No |
Physical |
|
colour | White |
Height | 148.5 cm |
Width | 52.1 cm |
Depth | 84.7 cm |
Net weight | 460 kg |
USB compatible | No |
Input |
|
network frequency | 40…70 Hz |
number of input connectors | 1 hard wire 4-wire (3P + E) 1 hard wire 5-wire (3P + N + E) |
input voltage limits | 340…460 V 400 V |
Maximum input current | 54 A |
Max short time withstand current | 65 kA |
Input harmonic distortion | Less than 3 % for full load |
Output |
|
Maximum configurable power in W | 40 kW |
Harmonic distortion | Less than 5 % |
output frequency | 50 Hz sync to mains 60 Hz sync to mains 50 Hz +/- 0.1 % for 50 Hz nominal unsynchronised 60 Hz +/- 0.1 % for 60 Hz nominal unsynchronised |
Crest factor | 2.5 |
Wave type | Sine wave |
Output voltage tolerance | +/-1% after 50ms |
Output overload operation | 10 minutes at 125% and 60 seconds at 150% |
Bypass type | Built-in static bypass |
Maximum configurable power in VA | 40 kVA |
Conformance |
|
Product certifications | UL 1778 5th edition |
Standards | CSA C22.2 No 107.3 EN/IEC 62040-1 EN/IEC 62040-2 EN/IEC 62040-3 IEC 60721-4-2 level 2M2 |
Environmental |
|
Ambient air temperature for operation | 0…40 °C |
relative humidity | 0…95 % non-condensing |
Operating altitude | 0…3281 ft |
Ambient air temperature for storage | -15…40 °C |
storage Relative Humidity | 0…95 % non-condensing |
Storage altitude | 0.00…3048.00 m |
Acoustic level | 61 dBA |
Heat dissipation | 4658 Btu/h |
IP degree of protection | IP20 |
Batteries & Runtime |
|
Efficiency | View Efficiency Graph
|
Battery voltage | 480 V |
discharge battery voltage | 384 V DC |
Max current discharge | 81 A |
Battery power in VAH | 0 VAh runtime |
Extended runtime | 0 |
Communications & Management |
|
Free slots | 1 |
control panel | Touch screen LCD user interface |
alarm | Audible and visible alarms prioritized by severity |
Packing Units |
|
Unit Type of Package 1 | PCE |
Number of Units in Package 1 | 1 |
Package 1 Height | 168 cm |
Package 1 Width | 99 cm |
Package 1 Length | 64 cm |
Package 1 Weight | 490 kg |
Contractual warranty |
|
Warranty | 1 year on-site repair or replace with factory authorized Start-Up |
Reviews
There are no reviews yet.