Rack PDU 2G, Switched, ZeroU, 20A, 208V, (21) C13 & (3) C19, L620 Cord – AP8959NA3
Overview
Switched Rack PDUFeatures & Benefits
Manageability
-
Remote Individual Outlet ControlRemotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up equipment (minimize costly downtime and avoid travel time to equipment).
-
Network Management CapabilitiesFull-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage rack PDUs from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.
-
Multi-tier user accessSupports up to four access levels – Administrator, Device User, Read-Only User and Network-only User – with user name and password requirements.
-
Local Current Monitoring DisplayThe aggregate current draw per rack PDU is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip. (Available on designated SKUs only)
-
Network port sharingAllows four rack PDUs to be connected using In and Out ports so that only one network connection is necessary.
-
Integrates with StruxureWare Data Center ExpertAn IT-ready, scalable access monitoring system that collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the network
-
Flash UpgradeableQuickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released. (Note: Networked units only)
-
Power DelaysAllows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up, which can cause overloaded circuits and dropped loads. Sequencing also allows users to predetermine which piece of equipment is turned on first so other equipment dependant on that unit will function properly.
-
Alarm ThresholdsDefine alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems. (Note: Only available on units with the current monitoring capabilities. Please see SKU specifications for availability)
Marketing Features
-
Power DelaysAllows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up, which can cause overloaded circuits and dropped loads. Sequencing also allows users to predetermine which piece of equipment is turned on first so other equipment dependant on that unit will function properly.
-
Remote Individual Outlet ControlRemotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up equipment (minimize costly downtime and avoid travel time to equipment).
-
Remote Management CapabilitiesFull-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage units from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.
-
Local Current Monitoring DisplayThe aggregate current draw per power distribution unit is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip.
-
Alarm ThresholdsDefine alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems.
Adaptability
-
Rack-MountableIncludes horizontal, vertical, and toolless-mount varieties. Puts power where it is needed most – in the racks near the equipment.
-
Single input power sourceSupply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount equipment. Saves time and money during installation by using one branch whip and standard connections.
-
Wide range of input and output connectionsProduct family includes a variety of input and output connections to distribute 120V, 208V, or 230V power to multiple outlets. Having a variety of inputs and outputs allow users to adapt to varying power requirements. APC offers units that bring up to 14.4kW using a single branch whip.
Detailed Tech Specification
Output
-
Nominal Output Voltage
208V
-
Overload Protection
No
-
Maximum Total Current Draw
16
-
Output Connections(3) IEC 320 C19 (Battery Backup)(21) IEC 320 C13 (Battery Backup)
Input
-
Nominal Input Voltage
200V , 208V , 230V
-
Input frequency
50/60 Hz
-
Input Connections
NEMA L6-20P
-
Cord Length
3meters
-
Acceptable Input Voltage
200-240VAC
-
Number of Power Cords
1
-
Maximum Input Current
20A
-
Regulatory Derated Input Current (North America)
16A
Physical
-
Maximum Height
1791mm , 179.1CM
-
Maximum Width
56mm , 5.6CM
-
Maximum Depth
46mm , 4.6CM
-
Net Weight
5.73KG
-
Shipping weight
8.59KG
-
Shipping Height
2002mm , 200.2CM
-
Shipping Width
165mm , 16.5CM
-
Shipping Depth
114mm , 11.4CM
-
Color
Black
-
Units per Pallet
48.0
Environmental
-
Operating Temperature
-5 – 45 °C
-
Operating Relative Humidity
5 – 95 %
-
Operating Elevation
0-3000meters
-
Storage Temperature
-25 – 65 °C
-
Storage Relative Humidity
5 – 95 %
-
Storage Elevation
0-15000meters
Conformance
-
Approvals
cUL Listed, EN 55022 Class A, EN 55024, EN 61000-3-2, EN 61000-3-3, FCC Part 15 Class A, ICES-003, PSE, UL Listed, VCCI Class A, VDE
-
Standard warranty
2 years repair or replace
Sustainable Offer Status
-
RoHS
Compliant
-
REACH
REACH: Contains No SVHCs
-
PEP
Available in Documentation tab
-
EOLI
Available in Documentation tab
-
Battery Directive
Compliant
-
Battery Notes
ts_Battery_Notes